SPECT/CT中xQuant重建算法的定量分析
02 November 2021
Ew-Jun Chen, Haniff Shazwan Safwan Selvama, Teik Hin Tan, Ming Tsuey Chew
摘要
Standard iterative Ordered Subset Expectation Maximisation (OSEM) reconstruction is well established in SPECT/CT, but despite its wide applications in image processing it comes with limitations in image noise and quality. A novel algorithm, xQuant (developed by Siemens Healthcare), uses Ordered Subset Conjugate Gradient Maximisation (OSCGM) which enables image quantification assessment such as standardised uptake value (SUV) measurements for reliable disease detection and evaluation of therapy response. As such, xQuant allows for dosimetry measurements, staging and management of diseases, analogous to the PET/CT modality for staging cancers and chemotherapy management. This study compares the accuracy of xQuant algorithm and current OSEM, by analysing image noise, SUV quantification and varying image reconstruction parameters. Standard clinical phantoms are used for comparison of both reconstruction algorithms: xQuant SUV accuracy with various Tc99m activity and varying scan times are performed for analysis. Results indicate that SUV measurements from xQuant are similar to expected SUV, regardless of selected reconstruction parameters, varying radiation activity and delayed scan times. Image noise assessment has shown that xQuant has lesser value of coefficient of variation (CoV) compared to standard OSEM, indicating xQuant's superior noise suppression without compromising image quality. The quantifiable superiority of xQuant reconstruction algorithm supersedes the basic iterative 3D OSEM reconstruction. It shows higher resolution qualitative assessment and provides consistent quantitative analysis. The reliability and superiority of xQuant enables clinical SPECT/CT quantification to detect disease and improve therapy management.
参考资料
- Aijing, H., et al. (2018). An improved OSEM iterative reconstruction algorithm for transmission tomographic gamma scanning. Applied Radiation and Isotopes.
- Castro, P., et al. (2018). Characterization and simulation of noise in PET images reconstructed with OSEM: Development of a method for the generation of synthetic images. Revista Española de Medicina Nuclear e Imagen Molecular.
- Chen, E.-J., et al. (2021). Superscan: Superiority of xSPECT/CT over OSEM SPECT/CT in bone scans of prostate cancer patients. Radiation Physics and Chemistry.
- Kinahan, P. E., et al. (2010). Positron emission tomography-computed tomography standardized uptake values in clinical practice and assessing response to therapy. Seminars in Ultrasound, CT and MRI.
- Toriihara, A., et al. (2018). Semiquantitative analysis using standardized uptake value in (123)I-FP-CIT SPECT/CT. Clinical Imaging.
- Ahn, S., et al. (2015). Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET. Physics in Medicine & Biology.
- Armstrong, I. S., et al. (2016). Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT. Nuclear Medicine Communications.
- Bailey, D. L., et al. (2013). An evidence-based review of quantitative SPECT imaging and potential clinical applications. Journal of Nuclear Medicine.
- Dickson, J., et al. (2019). Quantitative SPECT: The time is now. EJNMMI Physics.
- Duncan, I., et al. (2018). The clinical value of xSPECT/CT Bone versus SPECT/CT: A prospective comparison of 200 scans. European Journal of Hybrid Imaging.