摘要

Objective

Quantitative techniques to understand the contributing factors for repetitive stress injury among sonographers are limited. This study aims to quantify tendons stiffness in the upper extremities of upper sonographers during real-time imaging using shear wave elastography (SWE).

Methods

The subjects comprised seven healthy sonographers performing renal imaging on eight healthy volunteers with varied body mass index (BMI) in different positions. Stiffness measurements were taken on the right supraspinatus (SSP), abductor pollicis longus (APL), and common extensor tendon (CET) as the sonographers were performing their ultrasound.

Results

Sonographers with more work experience recorded higher stiffness in all three tendon groups compared to those with lesser experience (p < .05). The mean differences of stiffness in the SSP (0.26 m/s ± 0.10, p = .024) and CET (0.31 m/s ± 0.11, p = .013) were higher when scanning the sonographers in decubitus position. Significant differences were found in all three upper extremity tendons across four BMI categories of volunteers, with post-hoc test showing all tendons experiencing significantly higher stiffness when scanning overweight and obese volunteers compared with those of normal weight. General linear model-multivariate analysis indicated that BMI was the strongest predictor of stiffness (SSP [47.4%], APL [40.6%], and CET [39.5%] [p < .001]), followed by volunteers' position (SSP [11.6%] and CET [11.0%] [p < .001]).

Conclusion

Shear wave elastography can quantify real-time changes in tendon stiffness in ultrasound scanning. Participants' positioning and BMI have a greater impact on tendon strain, particularly on the SSP.


参考资料

  1. Al Saikhan, L. (2023). Prevalence, characteristics, consequences, and awareness of work-related musculoskeletal pain among cardiac sonographers compared with other healthcare workers in Saudi Arabia: A cross sectional study. PLOS ONE, 18(5), Article e0285369. https://doi.org/10.1371/journal.pone.0285369
  2. Arvidsson, I., Gremark Simonsen, J., Lindegård-Andersson, A., Björk, J., & Nordander, C. (2020). The impact of occupational and personal factors on musculoskeletal pain-a cohort study of female nurses, sonographers and teachers. BMC Musculoskeletal Disorders, 21(1), Article 641. https://doi.org/10.1186/s12891-020-03612-4
  3. Baker, J. P., & Coffin, C. T. (2013). The importance of an ergonomic workstation to practicing sonographers. Journal of Ultrasound in Medicine, 32(8), 1363–1375. https://doi.org/10.7863/ultra.32.8.1363
  4. Barr, A. E., Barbe, M. F., & Clark, B. D. (2004). Work-related musculoskeletal disorders of the hand and wrist: Epidemiology, pathophysiology, and sensorimotor changes. Journal of Orthopaedic & Sports Physical Therapy, 34(10), 610–627. https://doi.org/10.2519/jospt.2004.34.10.610
  5. Bastian, E. J., Kits, J. K., Weaver, J. D., Stevenson, J. R., Carlton, L., Raaymakers, S. A., & Vanderpoel, J. (2009). Effects of work experience, patient size, and hand preference on the performance of sonography studies. Journal of Diagnostic Medical Sonography, 25(1), 25–37. https://doi.org/10.1177/8756479308327060
  6. Baumgart, F. (2000). Stiffness—an unknown world of mechanical science? Injury, 31(Suppl 2), S-B14–S-B23. https://doi.org/10.1016/s0020-1383(00)80018-0
  7. Binder, M. D., Hirokawa, N., & Windhorst, U. (Eds.). (2009). Encyclopedia of neuroscience. Springer. https://doi.org/10.1000/978-3-540-29678-2
  8. Coffin, C. T. (2014). Work-related musculoskeletal disorders in sonographers: A review of causes and types of injury and best practices for reducing injury risk. Reports in Medical Imaging, 7, 15–26. https://doi.org/10.2147/RMI.S48128
  9. Davis, L. C., Baumer, T. G., Bey, M. J., & Van Holsbeeck, M. (2019). Clinical utilization of shear wave elastography in the musculoskeletal system. Ultrasonography, 38(1), 2–12. https://doi.org/10.14366/usg.18023
  10. Dhyani, M., Roll, S. C., Gilbertson, M. W., Orlowski, M., Anvari, A., Li, Q., Anthony, B., & Samir, A. E. (2017). A pilot study to precisely quantify forces applied by sonographers while scanning: A step toward reducing ergonomic injury. Work, 58(2), 241–247. https://doi.org/10.3233/WOR-172614
  11. Fukumura, Y. E., Sommerich, C. M., Evans, K. D., & Roll, S. C. (2024). Work-related musculoskeletal disorders and associated work systems factors: Are there differences between sonography practice areas? Journal of Diagnostic Medical Sonography, 40(1), 4–18. https://doi.org/10.1177/87564793231195655
  12. Gallagher, S., & Barbe, M. F. (2022). Musculoskeletal disorders: The fatigue failure mechanism. Wiley-Blackwell. https://doi.org/10.1002/9781119782520
  13. Haththotuwa, R. N., Wijeyaratne, C. N., & Senarath, U. (2020). Worldwide epidemic of obesity. In T. A. Mahmood, S. Arulkumaran, & F. A. Chervenak (Eds.), Obesity and obstetrics (pp. 3–8). Elsevier. https://doi.org/10.1016/B978-0-12-817921-5.00001-1
  14. Henningsen, C., Sayeed, Y., Bagley, J., Fields, C., Marroquin, J., Quevedo, M., Robinson, K., Roll, S., Wolfman, D., & Kummer, T. (2023). AIUM practice principles for WRMSDs. Journal of Ultrasound in Medicine, 42(5), 1139–1157. https://doi.org/10.1002/jum.16139
  15. Homack, S. R. (2001, February 1–3). Understanding what ANOVA post hoc tests are, really [Paper presentation]. Annual Meeting of the Southwest Educational Research Association, New Orleans, LA, United States. ERIC Document ED449222.
  16. Ito, N., Sigurðsson, H. B., Pohlig, R. T., Cortes, D. H., Grävare Silbernagel, K., & Sprague, A. L. (2023). Reliability of continuous shear wave elastography in the pathological patellar tendon. Journal of Ultrasound in Medicine, 42(5), 1047–1055. https://doi.org/10.1002/jum.16115
  17. Kinsella, S. B., & Carl, R. L. (2013). Upper extremity overuse injuries. Clinical Pediatric Emergency Medicine, 14(4), 318–326. https://doi.org/10.1016/j.cpem.2013.10.008
  18. Matsuhashi, T., Hooke, A. W., Zhao, K. D., Goto, A., Sperling, J. W., Steinmann, S. P., & An, K. N. (2014). Tensile properties of a morphologically split supraspinatus tendon. Clinical Anatomy, 27(5), 702–706. https://doi.org/10.1002/ca.22359
  19. McCulloch, M., Xie, T., & Adams, D. (2002). Cardiovascular sonography: The painful art of scanning. Cardiac Ultrasound Today, 8(5), 69–96.
  20. Muir, M., Hrynkow, P., Chase, R., Boyce, D., & Mclean, D. (2004). The nature, cause, and extent of occupational musculoskeletal injuries among sonographers: Recommendations for treatment and prevention. Journal of Diagnostic Medical Sonography, 20(5), 317–325. https://doi.org/10.1177/8756479304268603
  21. Murphey, S. (2017). Work related musculoskeletal disorders in sonography. Journal of Diagnostic Medical Sonography, 33(5), 354–369. https://doi.org/10.1177/8756479317726767
  22. Murphey, S., Milkowski, A., & Garman, A. (2003). SEMG evaluation of sonographer scanning postures. Ultrasound in Medicine and Biology, 29(5 Suppl), S19. https://doi.org/10.1016/S0301-5629(03)00135-2
  23. Pallotta, O., & Roberts, A. (2017). Musculoskeletal pain and injury in sonographers, causes and solutions. Sonography, 4(1), 5–12. https://doi.org/10.1002/sono.12093
  24. Pocratsky, J., Ashby, B., & Beasley, J. (2014). Upper extremity kinematics in sonographers during kidney scanning. Journal of Diagnostic Medical Sonography, 30(2), 67–76. https://doi.org/10.1177/8756479313516805
  25. Pruyn, E. C., Watsford, M. L., & Murphy, A. J. (2016). Validity and reliability of three methods of stiffness assessment. Journal of Sport and Health Science, 5(4), 476–483. https://doi.org/10.1016/j.jshs.2015.12.001
  26. Ryu, J., & Jeong, W. K. (2017). Current status of musculoskeletal application of shear wave elastography. Ultrasonography, 36(3), 185–197. https://doi.org/10.14366/usg.16043
  27. Schrope, B. A., & Goel, N. (2014). Physical principles of ultrasound. In E. Hagopian & J. Machi (Eds.), Abdominal ultrasound for surgeons (pp. 7–15). Springer. https://doi.org/10.1000/978-1-4939-0897-4_2
  28. Simonsen, J. G., Axmon, A., Nordander, C., & Arvidsson, I. (2017). Neck and upper extremity pain in sonographers–associations with occupational factors. Applied Ergonomics, 58, 245–253. https://doi.org/10.1016/j.apergo.2016.06.014
  29. Steinmann, S., Pfeifer, C. G., Brochhausen, C., & Docheva, D. (2020). Spectrum of tendon pathologies: Triggers, trails and end-state. International Journal of Molecular Sciences, 21(3), Article 844. https://doi.org/10.3390/ijms21030844
  30. Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017). Shear-wave elastography: Basic physics and musculoskeletal applications. RadioGraphics, 37(3), 855–870. https://doi.org/10.1148/rg.2017160116
  31. Tardioli, A., Malliaras, P., & Maffulli, N. (2012). Immediate and short-term effects of exercise on tendon structure: Biochemical, biomechanical and imaging responses. British Medical Bulletin, 103(1), 169–202. https://doi.org/10.1093/bmb/lds017
  32. Thomas, E., Ficarra, S., Nakamura, M., Paoli, A., Bellafiore, M., Palma, A., & Bianco, A. (2022). Effects of different long-term exercise modalities on tissue stiffness. Sports Medicine - Open, 8(1), Article 71. https://doi.org/10.1186/s40798-022-00462-7
  33. Village, J., & Trask, C. (2007). Ergonomic analysis of postural and muscular loads to diagnostic sonographers. International Journal of Industrial Ergonomics, 37(9–10), 781–789. https://doi.org/10.1016/j.ergon.2007.06.001
  34. Wang, L., Guo, X., Tan, L., & Chen, Q. (2021). Quantitative assessment of normal middle deltoid muscle elasticity at various arm abduction using ultrasound shear wave elastography. Scientific Reports, 11(1), Article 12479. https://doi.org/10.1038/s41598-021-91979-9
  35. Zangiabadi, Z., Makki, F., Marzban, H., Salehinejad, F., Sahebi, A., & Tahernejad, S. (2024). Musculoskeletal disorders among sonographers: A systematic review and meta-analysis. BMC Health Services Research, 24(1), Article 1233. https://doi.org/10.1186/s12913-024-11680-x
  36. Zhang, D., Yan, M., Lin, H., Xu, G., Yan, H., & He, Z. (2020). Evaluation of work-related musculoskeletal disorders among sonographers in general hospitals in Guangdong province, China. International Journal of Occupational Safety and Ergonomics, 26(4), 802–810. https://doi.org/10.1080/10803548.2019.1601372
  37. Zhang, J., Zhang, L., Guo, F., & Zhang, T. (2022). Shear wave elastography of the coracohumeral ligament with frozen shoulder in different stages. Journal of Ultrasound in Medicine, 41(10), 2527–2534. https://doi.org/10.1002/jum.15942

引用

Leong, Sooksam & Wong, Jeannie & Md Shah, Mohammad & Vijayananthan, Anushya & Azman, Raja. (2026). The Role of Shear Wave Elastography in Quantifying Tendon Stiffness in Upper Extremities of Sonographers: Reducing Work-Related Musculoskeletal Disorders. Workplace Health & Safety. 10.1177/21650799261450145. 

复制引用 已复制!